[docs]class ThorLabsAPT(_abstract.ThorLabsInstrument): """ Generic ThorLabs APT hardware device controller. Communicates using the ThorLabs APT communications protocol, whose documentation is found in the thorlabs source folder. """
[docs] class APTChannel(object): """ Represents a channel within the hardware device. One device can have many channels, each labeled by an index. """ def __init__(self, apt, idx_chan): self._apt = apt # APT is 1-based, but we want the Python representation to be # 0-based. self._idx_chan = idx_chan + 1 @property def enabled(self): """ Gets/sets the enabled status for the specified APT channel :type: `bool` """ pkt = _packets.ThorLabsPacket( message_id=_cmds.ThorLabsCommands.MOD_REQ_CHANENABLESTATE, param1=self._idx_chan, param2=0x00, dest=self._apt.destination, source=0x01, data=None ) resp = self._apt.querypacket( pkt, expect=_cmds.ThorLabsCommands.MOD_GET_CHANENABLESTATE) return not bool(resp.parameters[1] - 1) @enabled.setter def enabled(self, newval): pkt = _packets.ThorLabsPacket( message_id=_cmds.ThorLabsCommands.MOD_SET_CHANENABLESTATE, param1=self._idx_chan, param2=0x01 if newval else 0x02, dest=self._apt.destination, source=0x01, data=None ) self._apt.sendpacket(pkt)
_channel_type = APTChannel def __init__(self, filelike): super(ThorLabsAPT, self).__init__(filelike) self._dest = 0x50 # Generic USB device; make this configurable later. # Provide defaults in case an exception occurs below. self._serial_number = None self._model_number = None self._hw_type = None self._fw_version = None self._notes = "" self._hw_version = None self._mod_state = None self._n_channels = 0 self._channel = () # Perform a HW_REQ_INFO to figure out the model number, serial number, # etc. try: req_packet = _packets.ThorLabsPacket( message_id=_cmds.ThorLabsCommands.HW_REQ_INFO, param1=0x00, param2=0x00, dest=self._dest, source=0x01, data=None ) hw_info = self.querypacket( req_packet, expect=_cmds.ThorLabsCommands.HW_GET_INFO, expect_data_len=84 ) self._serial_number = codecs.encode(hw_info.data[0:4], 'hex').decode('ascii') self._model_number = hw_info.data[4:12].decode('ascii').replace('\x00', '').strip() hw_type_int = struct.unpack('<H', hw_info.data[12:14])[0] if hw_type_int == 45: self._hw_type = 'Multi-channel controller motherboard' elif hw_type_int == 44: self._hw_type = 'Brushless DC controller' else: self._hw_type = 'Unknown type: {}'.format(hw_type_int) # Note that the fourth byte is padding, so we strip out the first # three bytes and format them. # pylint: disable=invalid-format-index self._fw_version = "{0[0]:x}.{0[1]:x}.{0[2]:x}".format( hw_info.data[14:18] ) self._notes = hw_info.data[18:66].replace(b'\x00', b'').decode('ascii').strip() self._hw_version = struct.unpack( '<H', hw_info.data[78:80])[0] self._mod_state = struct.unpack( '<H', hw_info.data[80:82])[0] self._n_channels = struct.unpack( '<H', hw_info.data[82:84])[0] except IOError as e: logger.error("Exception occured while fetching hardware info: %s", e) # Create a tuple of channels of length _n_channel_type if self._n_channels > 0: self._channel = tuple(self._channel_type(self, chan_idx) for chan_idx in range(self._n_channels)) @property def serial_number(self): """ Gets the serial number for the APT controller :type: `str` """ return self._serial_number @property def model_number(self): """ Gets the model number for the APT controller :type: `str` """ return self._model_number @property def name(self): """ Gets the name of the APT controller. This is a human readable string containing the model, serial number, hardware version, and firmware version. :type: `str` """ return "ThorLabs APT Instrument model {model}, serial {serial} " \ "(HW version {hw_ver}, FW version {fw_ver})".format( hw_ver=self._hw_version, serial=self.serial_number, fw_ver=self._fw_version, model=self.model_number ) @property def channel(self): """ Gets the list of channel objects attached to the APT controller. A specific channel object can then be accessed like one would access a list. :type: `tuple` of `APTChannel` """ return self._channel @property def n_channels(self): """ Gets/sets the number of channels attached to the APT controller :type: `int` """ return self._n_channels @n_channels.setter def n_channels(self, nch): # Change the number of channels so as not to modify those instances # already existing: # If we add more channels, append them to the list, # If we remove channels, remove them from the end of the list. if nch > self._n_channels: self._channel = self._channel + \ list(self._channel_type(self, chan_idx) for chan_idx in range(self._n_channels, nch)) elif nch < self._n_channels: self._channel = self._channel[:nch] self._n_channels = nch
[docs] def identify(self): """ Causes a light on the APT instrument to blink, so that it can be identified. """ pkt = _packets.ThorLabsPacket( message_id=_cmds.ThorLabsCommands.MOD_IDENTIFY, param1=0x00, param2=0x00, dest=self._dest, source=0x01, data=None ) self.sendpacket(pkt)
@property def destination(self): """ Gets the destination for the APT controller :type: `int` """ return self._dest
class APTPiezoDevice(ThorLabsAPT): """ Generic ThorLabs APT piezo device, superclass of more specific piezo devices. """ class PiezoDeviceChannel(ThorLabsAPT.APTChannel): """ Represents a channel within the hardware device. One device can have many channels, each labeled by an index. This class represents piezo stage channels. """ # PIEZO COMMANDS # @property def max_travel(self): """ Gets the maximum travel for the specified piezo channel. :type: `~quantities.Quantity` :units: Nanometers """ pkt = _packets.ThorLabsPacket( message_id=_cmds.ThorLabsCommands.PZ_REQ_MAXTRAVEL, param1=self._idx_chan, param2=0x00, dest=self._apt.destination, source=0x01, data=None ) resp = self._apt.querypacket(pkt) # Not all APT piezo devices support querying the maximum travel # distance. Those that do not simply ignore the PZ_REQ_MAXTRAVEL # packet, so that the response is empty. if resp is None: return NotImplemented # chan, int_maxtrav _, int_maxtrav = struct.unpack('<HH', resp.data) return int_maxtrav * pq.Quantity(100, 'nm') @property def led_intensity(self): """ Gets/sets the output intensity of the LED display. :type: `float` between 0 and 1. """ pkt = _packets.ThorLabsPacket( message_id=_cmds.ThorLabsCommands.PZ_REQ_TPZ_DISPSETTINGS, param1=0x01, param2=0x00, dest=self._dest, source=0x01, data=None ) resp = self.querypacket(pkt) return float(struct.unpack('<H', resp.data)[0]) / 255 @led_intensity.setter def led_intensity(self, intensity): # pylint: disable=round-builtin pkt = _packets.ThorLabsPacket( message_id=_cmds.ThorLabsCommands.PZ_SET_TPZ_DISPSETTINGS, param1=None, param2=None, dest=self._dest, source=0x01, data=struct.pack('<H', int(round(255 * intensity))) ) self.sendpacket(pkt) _channel_type = PiezoDeviceChannel
[docs]class APTPiezoStage(APTPiezoDevice): """ Class representing a Thorlabs APT piezo stage """
[docs] class PiezoChannel(APTPiezoDevice.PiezoDeviceChannel): """ Class representing a single piezo channel within a piezo stage on the Thorlabs APT controller. """ # PIEZO COMMANDS # @property def position_control_closed(self): """ Gets the status if the position control is closed or not. `True` means that the position control is closed, `False` otherwise :tyep: `bool` """ pkt = _packets.ThorLabsPacket( message_id=_cmds.ThorLabsCommands.PZ_REQ_POSCONTROLMODE, param1=self._idx_chan, param2=0x00, dest=self._apt.destination, source=0x01, data=None ) resp = self._apt.querypacket( pkt, expect=_cmds.ThorLabsCommands.PZ_GET_POSCONTROLMODE) return bool((resp.parameters[1] - 1) & 1)
[docs] def change_position_control_mode(self, closed, smooth=True): """ Changes the position control mode of the piezo channel :param bool closed: `True` for closed, `False` for open :param bool smooth: `True` for smooth, `False` for otherwise. Default is `True`. """ mode = 1 + (int(closed) | int(smooth) << 1) pkt = _packets.ThorLabsPacket( message_id=_cmds.ThorLabsCommands.PZ_SET_POSCONTROLMODE, param1=self._idx_chan, param2=mode, dest=self._apt.destination, source=0x01, data=None ) self._apt.sendpacket(pkt)
@property def output_position(self): """ Gets/sets the output position for the piezo channel. :type: `str` """ pkt = _packets.ThorLabsPacket( message_id=_cmds.ThorLabsCommands.PZ_REQ_OUTPUTPOS, param1=self._idx_chan, param2=0x00, dest=self._apt.destination, source=0x01, data=None ) resp = self._apt.querypacket( pkt, expect=_cmds.ThorLabsCommands.PZ_GET_OUTPUTPOS) # chan, pos _, pos = struct.unpack('<HH', resp.data) return pos @output_position.setter def output_position(self, pos): pkt = _packets.ThorLabsPacket( message_id=_cmds.ThorLabsCommands.PZ_SET_OUTPUTPOS, param1=None, param2=None, dest=self._apt.destination, source=0x01, data=struct.pack('<HH', self._idx_chan, pos) ) self._apt.sendpacket(pkt)
_channel_type = PiezoChannel
[docs]class APTStrainGaugeReader(APTPiezoDevice): """ Class representing a Thorlabs APT strain gauge reader. .. warning:: This is not currently implemented """
[docs] class StrainGaugeChannel(APTPiezoDevice.PiezoDeviceChannel): """ Class representing a single strain gauge channel attached to a `APTStrainGaugeReader` on the Thorlabs APT controller. .. warning:: This is not currently implemented """ # STRAIN GAUGE COMMANDS # pass
_channel_type = StrainGaugeChannel
[docs]class APTMotorController(ThorLabsAPT): """ Class representing a Thorlabs APT motor controller """
[docs] class MotorChannel(ThorLabsAPT.APTChannel): """ Class representing a single motor attached to a Thorlabs APT motor controller (`APTMotorController`). """ # INSTANCE VARIABLES # _motor_model = None #: Sets the scale between the encoder counts and physical units #: for the position, velocity and acceleration parameters of this #: channel. By default, set to dimensionless, indicating that the proper #: scale is not known. #: #: In keeping with the APT protocol documentation, the scale factor #: is multiplied by the physical quantity to get the encoder count, #: such that scale factors should have units similar to microsteps/mm, #: in the example of a linear motor. #: #: Encoder counts are represented by the quantities package unit #: "ct", which is considered dimensionally equivalent to dimensionless. #: Finally, note that the "/s" and "/s**2" are not included in scale #: factors, so as to produce quantities of dimension "ct/s" and #: "ct/s**2" #: from dimensionful input. #: #: For more details, see the APT protocol documentation. scale_factors = (pq.Quantity(1, 'dimensionless'), ) * 3 _motion_timeout = pq.Quantity(10, 'second') __SCALE_FACTORS_BY_MODEL = { # TODO: add other tables here. re.compile('TST001|BSC00.|BSC10.|MST601'): { # Note that for these drivers, the scale factors are identical # for position, velcoity and acceleration. This is not true for # all drivers! 'DRV001': (pq.Quantity(51200, 'ct/mm'),) * 3, 'DRV013': (pq.Quantity(25600, 'ct/mm'),) * 3, 'DRV014': (pq.Quantity(25600, 'ct/mm'),) * 3, 'DRV113': (pq.Quantity(20480, 'ct/mm'),) * 3, 'DRV114': (pq.Quantity(20480, 'ct/mm'),) * 3, 'FW103': (pq.Quantity(25600 / 360, 'ct/deg'),) * 3, 'NR360': (pq.Quantity(25600 / 5.4546, 'ct/deg'),) * 3 }, re.compile('TDC001|KDC101'): { 'MTS25-Z8': (1 / pq.Quantity(34304, 'mm/ct'), NotImplemented, NotImplemented), 'MTS50-Z8': (1 / pq.Quantity(34304, 'mm/ct'), NotImplemented, NotImplemented), # TODO: Z8xx and Z6xx models. Need to add regex support to motor models, too. 'PRM1-Z8': (pq.Quantity(1919.64, 'ct/deg'), NotImplemented, NotImplemented), } } __STATUS_BIT_MASK = { 'CW_HARD_LIM': 0x00000001, 'CCW_HARD_LIM': 0x00000002, 'CW_SOFT_LIM': 0x00000004, 'CCW_SOFT_LIM': 0x00000008, 'CW_MOVE_IN_MOTION': 0x00000010, 'CCW_MOVE_IN_MOTION': 0x00000020, 'CW_JOG_IN_MOTION': 0x00000040, 'CCW_JOG_IN_MOTION': 0x00000080, 'MOTOR_CONNECTED': 0x00000100, 'HOMING_IN_MOTION': 0x00000200, 'HOMING_COMPLETE': 0x00000400, 'INTERLOCK_STATE': 0x00001000 } # IK-SPECIFIC PROPERTIES # # These properties don't correspond to any particular functionality # of the underlying device, but control how we interact with it. @property def motion_timeout(self): return self._motion_timeout @motion_timeout.setter def motion_timeout(self, newval): self._motion_timeout = assume_units(newval, pq.second) # UNIT CONVERSION METHODS # def _set_scale(self, motor_model): """ Sets the scale factors for this motor channel, based on the model of the attached motor and the specifications of the driver of which this is a channel. :param str motor_model: Name of the model of the attached motor, as indicated in the APT protocol documentation (page 14, v9). """ for driver_re, motor_dict in self.__SCALE_FACTORS_BY_MODEL.items(): if driver_re.match(self._apt.model_number) is not None: if motor_model in motor_dict: self.scale_factors = motor_dict[motor_model] return else: break # If we've made it down here, emit a warning that we didn't find the # model. logger.warning("Scale factors for controller %s and motor %s are " "unknown", self._apt.model_number, motor_model) # We copy the docstring below, so it's OK for this method # to not have a docstring of its own. # pylint: disable=missing-docstring
[docs] def set_scale(self, motor_model): warnings.warn( "The set_scale method has been deprecated in favor " "of the motor_model property.", DeprecationWarning ) return self._set_scale(motor_model)
set_scale.__doc__ = _set_scale.__doc__ @property def motor_model(self): """ Gets or sets the model name of the attached motor. Note that the scale factors for this motor channel are based on the model of the attached motor and the specifications of the driver of which this is a channel, such that setting a new motor model will update the scale factors accordingly. :type: `str` or `None` """ return self._motor_model @motor_model.setter def motor_model(self, newval): self._set_scale(newval) self._motor_model = newval # MOTOR COMMANDS # @property def status_bits(self): """ Gets the status bits for the specified motor channel. :type: `dict` """ # NOTE: the difference between MOT_REQ_STATUSUPDATE and # MOT_REQ_DCSTATUSUPDATE confuses me pkt = _packets.ThorLabsPacket( message_id=_cmds.ThorLabsCommands.MOT_REQ_STATUSUPDATE, param1=self._idx_chan, param2=0x00, dest=self._apt.destination, source=0x01, data=None ) # The documentation claims there are 14 data bytes, but it seems # there are sometimes some extra random ones... resp_data = self._apt.querypacket(pkt).data[:14] # ch_ident, position, enc_count, status_bits _, _, _, status_bits = struct.unpack( '<HLLL', resp_data) status_dict = dict( (key, (status_bits & bit_mask > 0)) for key, bit_mask in self.__STATUS_BIT_MASK.items() ) return status_dict @property def position(self): """ Gets the current position of the specified motor channel :type: `~quantities.Quantity` """ pkt = _packets.ThorLabsPacket( message_id=_cmds.ThorLabsCommands.MOT_REQ_POSCOUNTER, param1=self._idx_chan, param2=0x00, dest=self._apt.destination, source=0x01, data=None ) response = self._apt.querypacket( pkt, expect=_cmds.ThorLabsCommands.MOT_GET_POSCOUNTER) # chan, pos _, pos = struct.unpack('<Hl', response.data) return pq.Quantity(pos, 'counts') / self.scale_factors[0] @property def position_encoder(self): """ Gets the position of the encoder of the specified motor channel :type: `~quantities.Quantity` :units: Encoder ``counts`` """ pkt = _packets.ThorLabsPacket( message_id=_cmds.ThorLabsCommands.MOT_REQ_ENCCOUNTER, param1=self._idx_chan, param2=0x00, dest=self._apt.destination, source=0x01, data=None ) response = self._apt.querypacket( pkt, expect=_cmds.ThorLabsCommands.MOT_GET_ENCCOUNTER) # chan, pos _, pos = struct.unpack('<Hl', response.data) return pq.Quantity(pos, 'counts')
[docs] def go_home(self): """ Instructs the specified motor channel to return to its home position """ pkt = _packets.ThorLabsPacket( message_id=_cmds.ThorLabsCommands.MOT_MOVE_HOME, param1=self._idx_chan, param2=0x00, dest=self._apt.destination, source=0x01, data=None ) _ = self._apt.querypacket(pkt, expect=_cmds.ThorLabsCommands.MOT_MOVE_HOMED, timeout=self.motion_timeout )
[docs] def move(self, pos, absolute=True): """ Instructs the specified motor channel to move to a specific location. The provided position can be either an absolute or relative position. :param pos: The position to move to. Provided value will be converted to encoder counts. :type pos: `~quantities.Quantity` :units pos: As specified, or assumed to of units encoder counts :param bool absolute: Specify if the position is a relative or absolute position. ``True`` means absolute, while ``False`` is for a relative move. """ # Handle units as follows: # 1. Treat raw numbers as encoder counts. # 2. If units are provided (as a Quantity), check if they're encoder # counts. If they aren't, apply scale factor. if not isinstance(pos, pq.Quantity): pos_ec = int(pos) else: if pos.units == pq.counts: pos_ec = int(pos.magnitude) else: scaled_pos = (pos * self.scale_factors[0]) # Force a unit error. try: pos_ec = int(scaled_pos.rescale(pq.counts).magnitude) except: raise ValueError("Provided units are not compatible " "with current motor scale factor.") # Now that we have our position as an integer number of encoder # counts, we're good to move. pkt = _packets.ThorLabsPacket( message_id=_cmds.ThorLabsCommands.MOT_MOVE_ABSOLUTE if absolute else _cmds.ThorLabsCommands.MOT_MOVE_RELATIVE, param1=None, param2=None, dest=self._apt.destination, source=0x01, data=struct.pack('<Hl', self._idx_chan, pos_ec) ) _ = self._apt.querypacket( pkt, expect=_cmds.ThorLabsCommands.MOT_MOVE_COMPLETED, timeout=self.motion_timeout )
_channel_type = MotorChannel